Slit lamp FREY SL-100 Haag-Streit
The new LED slit lamp by FREY S.J. is designed for very high performance and reliability. High quality optics assures excellent image quality and resolution. The digital slit lamp addresses the need for new technologies by integrating eye illumination and digital camera control electronics and features an innovative LED illumination system.
Easy to use and complete
Digital slit lamp SL-100 comes with all elements important for demanding user. Yellow filter is integrated into the optical body of the microscope, you can easily drop it in whenever you are looking for subtle corneal staining. The diffuser mounted to column hardware can be easily inserted into slit illumination path for improved general overview of the eye.
Digital camera ready
Digital slit lamp integrates all components and cabling required for connecting and controlling digital camera systems. Push button embedded into the joystick and the eye illumination system control electronics integrated within the device hardware assures no need for future upgrades in order to add a camera system. All connectors and cables for the camera connection are in an elegant way hidden inside to improve comfort of using the device.
LED illumination system
The digital slit lamp LED illumination source eliminated heat and infra red emission associated with traditional light sources. Emitted color temperature is independent of its intensity to guarantee a bright and clear picture. The lifecycle of LED is longer than 50 000 working hours, this eliminates maintenance associated with light source replacement. Digital slit lamp electronic circuit controlling LED light intensity are very precise for best slit light performance and control.
SL-100 TECHNICAL SPECIFICATION
SLIT, PROJECTION SYSTEM AND BASE GENERAL DATA
Minimum slit opening – 0 mm
Slit maximum lenght – 14 mm
Continuously adjustable slit length – 1.8 – 14 mm continuously variable
Slit projection scale – 1.2 x
Slit aperture diaphragms – 0.2/ 1/ 3/ 5.5/ 9/ 14 mm
Filters – clear, blue, natural density, yellow, diffuser, red-free
Slit rotation – 0° – 180° with a reference scale
Vertical slit tilting angles – 0°/ 5°/ 10°/ 15°/ 20°
Working distance – eye of patient / prism surface – 75 mm
Fixation lamp – green lamp
Chin-rest height adjustment 59 mm
Base travel – 103 mm X–axis, 100 mm Y–axis, 35 mm Z–axis
STEREOSCOPIC MICROSCOPE
Microscope type – Convergent binocular optical microscope @ 8°
Magnification power selection system – Five position rotating drum
Eyepiece – 12.5 x
Magnifying powers – 6x/ 10x/ 16x/ 25x/ 40x
Field of view [mm] – 36/ 22/ 14/ 9/ 5.6
Distance between pupils – 48.5 – 80 mm
Objective lens working distance – 111 mm
Objective lens working angle – 12°
Eyepiece diopter adjustment – from -5D to +5D
FREY SLI-200 Digital Imaging System
Frey SLI-200 provides unique quality with fully integrated design already at manufacture stage and does not require external PC. Implement efficient, high-level work flow and integration into clinical practice, with less complicated and more integrated device.
Stream to multiple screens
Stream images and videos across multiple devices. Frey SLI-200 allows you to collaborate with other health care professionals, share knowledge and discuss diagnosis, improve clinical outcomes in real time, easily. Ideal for general practices, educational and training institutions. Video streaming and photo sharing enhance clinical collaboration and education.
Stunning AMOLED tech
AMOLED screen provides superb image quality – better contrast, higher brightness, fuller viewing angle, a wider colour range to capture even the greatest detail of the eye. AMOLED consume less power, enables Frey to simplify the unique design that is ultra-thin with better durability.
Work wirelessly
Use fast, stable and reliable Wi-Fi AC or Bluetooth 4.2 to connect all your devices. Simplify workspace and improve clinical workflows
Out of the box & stand alone
Work independently and efficiently. Frey SLI-200 does not require external PC or any other device to operate. All cables remain hidden in an ergonomic and minimalistic design. The eye lighting system, which can be controlled using the knob built into the lamp base, is included.
Large & reliable internal storage
Result and image management is an essential part of doctor’s workflow. SLI-200 simplifies and speeds up the work with 128GB internal storage. Gather a large number of heavy files. Select, the most interesting photos and sent them to you smartphone – without cluttering it.
TECHNICAL SPECIFICATION
Device type – SLI-200 Imaging System
Screen – AMOLED 5’ touch screen
Sensor – CMOS Image Sensors with a 3.45 μm Pixel
Memory – 128 GB internal high endurance flash storage
Image processing technology – HDR, Global Shutter Function
Photo resolution – 2048×1536 px
Movie resolution – 960×720 px
Communication – Bluetooth 4.2, Wi-Fi AC
Depht of colour – up to 12 BPP
Other features
- Video streaming to multiple devices
- Photo & video captur
- Automatic L/R eye detection